Skip to main content
07816 434 770

Misted Double Glazing: Repair or Replace?

Misted double glazing means the seal around a sealed glass unit has failed and moist air has got between the two panes. Wiping it will not help because the moisture is inside. In most cases only the sealed unit needs replacing, not the whole window, as long as the frame and hinges are sound.

Misted double glazing replaced with a new sealed unit in Derby

Written by AJB Windows Doors & Conservatories. Last reviewed: October 2026

At a glance

Cause
A failed edge seal on the sealed glass unit
Usual fix
Replace the sealed unit and keep the frame
Replace the window when
The frame is damaged, warped or the window is very inefficient
Building regulations
Glass-only replacement is a repair, not controlled work
First check
Whether the unit is still under guarantee

Why does double glazing mist up between the panes?

Double glazing mists up between the panes because the seal around the edge of the sealed unit has failed. Once the seal goes, damp air gets into the gap and condenses on the cold glass.

Seals age over time. Constant heating and cooling, sun on south-facing windows and water sitting in a frame that does not drain properly can all speed this up.

Is the condensation inside, outside or between the panes?

Where the condensation sits tells you what it means:

What condensation on double glazing means
Where it formsWhat it meansWhat to do
Room sideHumid air in the room meeting cooler glassImprove ventilation; not a fault with the window
Outside faceCommon on cold mornings with well-insulating glassNothing; it clears as the day warms
Between the panesThe sealed unit has failedReplace the sealed unit

Should I repair misted double glazing or replace the window?

Replace just the sealed unit if the frame, hinges and locks are in good condition. It is quicker and cheaper than a new window, and the frame stays in place.

Replace the whole window if the frame is rotten, warped or cracked, if several units have failed at once, or if the window is old and inefficient. A whole new window must meet current building regulations; a new sealed unit alone does not.

Some services drill and dry misted units. Results vary, and drying does not restore the original seal, so a new sealed unit is the more reliable fix.

What happens when a misted unit is replaced?

Replacing a misted sealed unit usually follows these steps:

  1. Measure. The installer measures the glass and notes the glass type, such as toughened or obscure.
  2. Order. A new sealed unit is made to size.
  3. Remove. The glazing beads are taken off and the old unit lifted out.
  4. Fit. The new unit is packed and seated in the frame.
  5. Finish. The beads go back on and the window is checked for smooth opening.
Your questions answered

What else do people ask about misted double glazing?

Can misted double glazing be fixed?

Yes. The usual fix is to replace the sealed glass unit while keeping the existing frame. This works as long as the frame, hinges and locks are in good condition.

Do I need a new window if my double glazing is misted?

Usually not. Only the sealed unit needs replacing unless the frame is damaged, warped or the window is old and inefficient.

Why is there condensation between my double glazing panes?

Condensation between the panes means the seal around the sealed unit has failed and damp air has got inside. It cannot be wiped away because it is inside the unit.

Is misted double glazing less energy efficient?

Yes, usually. A failed seal can let the insulating gas escape and moisture in, so the unit no longer insulates as well as it did.

Do I need building regulations approval to replace a misted unit?

No. Replacing only the sealed glass unit is a repair, not controlled building work. The new glass must still be safety glass where the location requires it.

AJB Windows installers fitting windows in Derby
Get in touch today

Need advice on your windows or doors?

Please don't hesitate to get in touch for any window or door installation work. No job is too big or small and we welcome all enquiries.